The microprocessor controlled high efficiency laboratory power supplies of series EA-PS 9000 3U offer many functions and features in their standard version, making the use of this equipment remarkably easy and most effective. The clearly arranged control panel features two rotary knobs, six pushbuttons and two LEDs. Together with a colour TFT display for all values and status it simplifies the use of the devices.

  • Multi-phase input 340…460 VAC or 188…229 VAC (US)
  • High efficiency up to 93%
  • Output power ratings: 0…6,6 kW
  • Output voltages: 0…40 V 
  • Output currents: 0…340 A 
  • Auto-ranging output stage
  • Various protection circuits (OVP, OCP, OPP, OTP) 
  • Control panel with pushbuttons and colour TFT for actual values, set values, status and alarms
  • Galvanically isolated, analog interface
  • Temperature controlled fans for cooling
  • 40 V models according to SELV (EN 60950)
  • Discharge circuit (Uout < 60 V in ≤ 10 s)
  • USB and Ethernet port integrated or alternatively installed IEEE/GPIB port
  • EMC TÜV approved for EN 61010 Class B
  • SCPI command language supported
  • Weight 24 kg
  • Dimension (B x H x T) 19 Zoll x 3HE/U x 609 mm

AC SUPPLY

All models are provided with an active Power Factor Correction circuit and are designed for a usage on a three-phase supply with 340 V up to 460 V AC (models for the european market) or 188 V up to 229 V AC (US models).

POWER

The devices are equipped with a flexible auto-ranging output stage which provides a higher output voltage at lower output current, or a higher output current at lower output voltage, always limited to the max. nominal output power. Therefore, a wide range of applications can already be covered by the use of just one unit.

DC OUTPUT

DC output voltages between 0…40 V and 0…1500 V, output currents between 0…20 A and 0…510 A and output power ratings of 0…3.3 kW, 0…5 kW, 0…6.6 kW, 0…10 kW or 0…15 kW are available. The output terminal is located in the rear panel.

DISCHARGE CIRCUIT

Models with a nominal output voltage of 200 V or higher include a discharge circuit for the output capacities. For no load or low load situations, it ensures that the dangerous output voltage can sink to under 60 V DC after the DC output has been switched off. This value is considered as limit for voltages dangerous to human safety.

PROTECTIVE FEATURES

For protection of the equipment connected, it is possible to set an overvoltage protection threshold (OVP), as well as one for overcurrent (OCP) and overpower (OPP). As soon as one of these thresholds is reached for any reason, the DC output will be immediately shut off and a status signal will be generated on the display and via the interfaces. There is furthermore an overtemperature protection, which will shut off the DC output if the device overheats.

DISPLAY AND CONTROLS

All important information is clearly visualised on a colour TFT display. With this, information about the actual output values and set values of voltage and current, the actual control state (CV, CC, CP) and other statuses, as well as alarms and settings of the setup menu are clearly displayed. In order to ease adjusting of values by the rotary knobs, pushing them can switch between decimal positions of a value. All these features contribute to an operator friendliness. With a panel lock feature, the whole panel can be locked in order to protect the equipment and the loads from unintentional misuse.

REMOTE SENSING

The standard sensing input can be connected directly to the load in order to compensate voltage drops along the power cables. If the sensing input is connected to the load, the power supply will adjust the output voltage automatically to ensure the required voltage is available at the load.

DIGITAL INTERFACES

All models features two galvanically isolated, digital interfaces by default (standard: 1x USB & 1x Ethernet, with option 3W: 1x USB & 1x GPIB), which are located on the rear side. USB and Ethernet can be used to control and monitor the devices either with SCPI language commands or ModBus RTU protocol, while with GPIB only SCPI is supported.

ANALOG INTERFACE

There is a galvanically isolated analog interface terminal, located on the rear of the device. It offers analog inputs to set voltage, current and power from 0…100% through control voltages of 0…10 V or 0…5 V.
To monitor the output voltage and current, there are analog outputs with voltage ranges of 0…10 V or 0…5 V. Also, several status inputs and outputs are available.

OPTIONS

  • High speed ramping (upon request, also see page 144)
  • Water cooling (upon request, also see page 145)
  • Three-way interface (3W) with a rigid GPIB port installed instead of the default Ethernet port
  • * Not available for all voltages - please quote for availability

#06230256

Additional product information

Handbook Download

Browse this category: PS 9000 3U Series