FSP065-P35-A12 OPEN FRAME
This AC-DC switching power supplies in a package of 3 x 5 inches is a compact Class-II PSU and no load power consumption less than 0.21 W. This PSU is capable of delivering 65 W continuous power at convection cooling and 50℃ operation temperature. Product is suitable for audio & video, display, information, and networking application.
FEATURES:
- Class II, Design entspricht IEC 60950-1, IEC 60065 -1, IEC62368-1, EN 61558-1
- High quality components
- No load power cunsumption ≦ 0.21 W
- Efficiency: 88%
- Over temperature-, over voltage-, short circuit protection, “Brown out”- (75 VAC)
- Operating temperature: -20°C up to 70°C
- Storage temperature: -40°C up to 85°C
- Certified up to 5000 m operating altitude
SPECIFICATIONS:
- 65 W, 12 V
- Design: Open frame
- AC input: Wide input voltage range 90 - 264 VAC
- Input frequency: 47 - 63 Hz
- Derate from 100% at +50℃ linearly to 50% at +70℃, applicable to convection cooling condition
- Dimensions: 127 x 76.2 x 28.6 mm (L x W x H)
3” x 5” x 1.126”
- Weight: 200 grams, (0.44 lbs.) approx.
- Safty: CE, UL, cUL, CB, CSA,
IEC 62368-1, UL 62368-1, CAN/CSA 22.2 No.62368-1-14
- ROHS
- EMC Performance
EN55032 Class B conducted, class B radiated
FCC: Class B conducted, class B radiated
VCCI: Class B conducted, class B radiated
EN61000-3-2: Harmonic distortion, class A
EN61000-3-3: Line flicker
EN61000-4-2: ESD, ±8 KV air and ±4 KV contact
EN61000-4-3: Radiated immunity, 3 V/m
EN61000-4-4: Fast transient/burst, ±1 KV
EN61000-4-5: Surge, ±2 KV diff, ±4 KV com
EN61000-4-6: Conducted immunity, 3 Vrms
EN61000-4-8: Magnetic field immunity, 3 A/m
EN61000-4-11: Voltage dip immunity, 240 Vac
30% reduction for 500 ms, criteria A
>95% reduction for 10 ms, criteria A
>95% reduction for 5000 mS, criteria B
A specification and various certificates is available and can be send by email.