1 - 1 of 18 results

EA-PS9040-401U, DC-Power Supply 1 chan 40V, 40A, 1 kW, USB, analog, LAN #06230219

Product no.: EA-06230219

Not in stock
This product is subject to possible delivery delays.

2,132.00
Price incl. VAT, plus delivery

EA-PS9040-402U DC-Laboratory power supply, 1 channel, 40 V, 40 A, 1 kW, USB, LAN, analog

This product is order related with an standard delivery time of approx. 8 - 10 weeks. 

The microprocessor controlled laboratory power supplies of series EA-PS 9000 2U offer many functions and features in their standard version, making the use of this equipment remarkably easy and most effective. The clearly arranged control panel features two rotary knobs, six pushbuttons and two LEDs. Together with a colour TFT display for all values and status it simplifies the use of the device.

  • Wide input voltage range 90…264 V, with active PFC (1000/1500 W Model)
  • High efficiency up to 92%
  • Output power ratings: 0...1000 W 
  • Output voltages: 0…40 V 
  • Output currents: 0…40 A 
  • Flexible, power regulated output stage
  • Various protection circuits (OVP, OCP, OPP, OTP)
  • Control panel with pushbuttons and colour TFT for actual values, set values, status and alarms
  • Galvanically isolated, analog interface with
  • 40 V models according to SELV (EN 60950)
  • Discharge circuit (Uout < 60 V in ≤ 10 s)
  • USB and Ethernet port integrated or alternatively installed IEEE/GPIB port
  • EMC according to EN 55022 Class B
  • SCPI command language supported
  • Weight ca. 12 kg 
  • Dimension (B x H x T) 19 Zoll x 2HE/U x 463 mm

AC SUPPLY

All units are provided with an active Power Factor Correction circuit and models up to 1.5 kW are even suitable for a worldwide operation on a supply from 90 VAC up to 264 VAC. With the 1.5 kW models, the output power is automatically reduced to 1 kW if the supply voltage is <150 VAC and with the 3 kW models is reduced to 2.5 kW at <205 VAC.

POWER

All models are equipped with a flexible auto-ranging output stage which provides a higher output voltage at lower output current, or a higher output current at lower output voltage, always limited to the max. nominal output power. The power set value is adjustable with these models. Therefore, a wide range of applications can already be covered by the use of just one unit.

DC OUTPUT

DC output voltages between 0…40 V and 0…750 V, output currents between 0…4 A and 0…120 A and output power ratings between 0…1000 W and 0…3000 W are available. Current, voltage and power can thus be adjusted continuously between 0% and 100%, no matter if manually or remotely controlled (analog or digital). The DC output is located on the rear panel of the devices.

DISCHARGE CIRCUIT

Models with a nominal output voltage of 200 V or higher include a discharge circuit for the output capacities. For no load or low load situations, it ensures that the dangerous output voltage can sink to under 60 V DC after the DC output has been switched off. This value is considered as limit for voltages dangerous to human safety.

PROTECTIVE FEATURES

For protection of the equipment connected, it is possible to set an overvoltage protection threshold (OVP), as well as one for overcurrent (OCP) and overpower (OPP). As soon as one of these thresholds is reached for any reason, the DC output will be immediately shut off and a status signal will be generated on the display and via the interfaces. There is furthermore an overtemperature protection, which will shut off the DC output if the device overheats.

DISPLAY AND CONTROLS

All important information is clearly visualised on a colour TFT display. With this, information about the actual output values and set values of voltage and current, the actual control state (CV, CC, CP) and other statuses, as well as alarms and settings of the setup menu are clearly displayed. In order to ease adjusting of values by the rotary knobs, pushing them can switch between decimal positions of a value. All these features contribute to an operator friendliness. With a panel lock feature, the whole panel can be locked in order to protect the equipment and the loads from unintentional misuse.

ANALOG INTERFACE

There is a galvanically isolated analog interface terminal, located on the rear of the device. It offers analog inputs to set voltage, current and power from 0…100% through control voltages of 0 V…10 V or 0 V…5 V. To monitor the output voltage and current, there are analog outputs with voltage ranges of 0 V…10 V or 0 V…5 V. Also, several inputs and outputs are available for controlling and monitoring the device status.

DIGITAL INTERFACES

All models features two galvanically isolated, digital interfaces by default (standard: 1x USB & 1x Ethernet, with option 3W: 1x USB & 1x GPIB), which are located on the rear side. USB and Ethernet can be used to control and monitor the devices either with SCPI language commands or ModBus RTU protocol, while with GPIB only SCPI is supported.

SOFTWARE AND PROGRAMMING

For remote control from a Windows PC there is a software EA Power Control included with the device. It can be used with multiple different or identical models of series PS 9000 2U to monitor and control the units. The software furthermore includes a firmware update tool, as well as a feature to record data and to control the units by a semi-automatic table processing. For even more sophisticated, customer specific applications there is a complete programming documentation and also LabView VIs for direct implementation available.
All models of series PS 9000 2U support the common command language SCPI and the ModBus RTU protocol via both, Ethernet and USB. Models with option 3W can only use SCPI via the GPIB port. Programmierbare DC-Labornetzgeräte / Programmable laboratory DC Power supplies EA-PS 9000 2U 1000 W - 3000 W

REMOTE SENSING

Remote sensing can be done via a dedicated input which is directly connected to the load equipment, in order to compensate voltage drops along the load cables. The power supply detects automatically whether the sensing input is connected and will stabilise the voltage directly at the load. The connection for the remote sensing is located on the rear of the device.

OPTIONS

  • Three-way interface (3W) with a rigid GPIB port installed instead of the default Ethernet port

#06230219

Additional product information

Handbook Download

Browse this category: PS 9000 2U Series