FSP150-P35-A24 Industrial Switching Power Supply, 150 W, 24 V, Open Frame, AC/DC, 3 x 5 inches

Product no.: 150-99999-9OC1507700

Not in stock
This product is subject to possible delivery delays.

30.70
Price incl. VAT, plus delivery

FSP150-P35-A24 OPEN FRAME

This AC-DC switching power supplies in a package of 3 x 5 inches is a Class-I PSU and no load power consumption less than 0.21W. This PSU is capable of delivering 150 w continuous power at 7 CFM forced air cooling or 100 w continuous power at convection cooling and 50℃ operation temperature. Product is suitable for information, display, industrial and telecom applications.

FEATURES:

  • Class I
  • High quality components
  • No load power cunsumption ≦ 0.21A
  • Efficiency: 92%
  • Over temperature-, over voltage-, over current-, short circuit protection, “Brown out”- (75 VAC)
  • Operating temperature: -20°C up to 70°C
  • Storage temperature: -40°C up to 85°C
  • Certified up to 5000 m operating altitude

SPECIFICATIONS:

  • 150 W, 24 V 
  • Design: Open frame
  • AC input: Wide input voltage range 90 - 264 VAC
  • Input frequency: 47 - 63 Hz
  • Derate from 100% at +50℃ linearly to 50% at +70℃, applicable to both convection and forced-air cooling conditions
  • Dimensions: 127 x 76.2 x 28.6 mm (L x W x H)
                          3” x 5” x 1.126”
  • Weight: 220 grams, (0.485 lbs.) approx.
  • Safty: CE, UL, cUL, CB, CSA, 
    IEC 62368-1, UL 62368-1, CAN/CSA 22.2 No.62368-1-14
  • ROHS
  • EMC Performance
    EN55032 Class B conducted, class B radiated
    FCC: Class B conducted, class B radiated
    VCCI: Class B conducted, class B radiated
    EN61000-3-2: Harmonic distortion, class A and D
    EN61000-3-3: Line flicker
    EN61000-4-2: ESD, ±8 KV air and ±4 KV contact
    EN61000-4-3: Radiated immunity, 3 V/m
    EN61000-4-4: Fast transient/burst, ±1 KV
    EN61000-4-5: Surge, ±2 KV diff, ±4 KV com
    EN61000-4-6: Conducted immunity, 3 Vrms
    EN61000-4-8: Magnetic field immunity, 1 A/m
    EN61000-4-11: Voltage dip immunity,
    30% reduction for 500 ms, criteria A
    >95% reduction for 10 ms, criteria A
    >95% reduction for 5000 mS, criteria B

A specification and various certificates is available and can be send by email.

Additional product information

Handbook Download

Browse this category: Open Frame AC-DC Switching Power Supply